division of BIOLAB |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Larson Davis Industrial Hygiene & Worker
Safety Products
Spark™ 705 & 705+ Super-duty Noise Dosimeters
|
|
Features |
|
Spark™ Dosimeter "Combo-paks"
Spark Dosimeter 'Combo-paks' Take full advantage of the awesome power of 'I2CU' with our convenient 'Combo-paks' consisting of multiple 705+ Remote Response Dosimeters and a single 706RC Master Controller Dosimeter - which performs triple duty as a stand-alone Dosimeter, and Integrating Sound Level Meter, too!
Model Description Major Features
705 Logging dosimeter Downloads basic and summary reports to PC. The 705 is controlled by the PC with Blaze™ software
705+ Fully featured Super-duty logging dosimeter with remote response capability Complete report generation and analysis using Blaze™ software. Can be operated capability and interrogated by the 706RC, or from the PC directly.
706RC Fully featured logging dosimeter/ISLM with remote control capability Full report generation and analysis using Blaze™ software. Gives surrogate display capability for 705+. The remote control function allows setup and control of other remote response Sparks. Interrogates and stores data from multiple dosimeters.
Nose Exposure Analysis Software for Spark™
For creating first-class reports and identifying at-risk population groups, Spark's companion Blaze™ Software is unbeatable - need a concise OSHA compliance report and a clearly understood color graph of work-shift exposure combined on one page? Just click and there it is - with overexposure conditions clearly marked. Want to illustrate the effectiveness of proposed controls on that very same page? It's done in a snap! New regulations looming? Don't worry, with the dose re-calculation function, you've got it covered!
Specifications
Measurement range: 40 to 143 dB (RMS); 80 to 146 dB (peak) typical
Max peak level: 146 dB SPL
Detectors: Slow, fast, and peak
Frequency weighting: A, C, Unweighted (Peak)
Microphone: 3/8" electret
Memory: 1 MB, non-volatile
Clock/calendar: Month, day, year, hh:mm:ss
Power supply: Internal: One AA battery, 35 hrs. operation
Dimensions: 3.9" L x 2.9" W x .78" D
Weight: 7.0 oz. (198 g)
Standards met: ANSI S1.4 - 1983, ANSI S1.25 - 1991 IEC 60651 - 1993, IEC 60804 - 1993, IEC 61252 - 1993 compliant
Instrinsic Safety Standards Met: ANSI/UL 913, ANSI/UL 2279 part 11 CSA-157, CSA-E70-11 (Canada) IEC 60079-11 EN 50020 (Europe)
Accessories (Included)
MPR001: Detachable prepolarized electret microphone
I706.01: User Manual
0255.0005: AA battery
3910.0014: Mic Clip
WS002: Windscreen
Accessories (Optional)
DVX008: PC external infrared data acquisition (IrDA) serial adaptor
CAL150: Calibrator with 94 or 114 dB output @ 1 kHz
SWW_BLAZE: Blaze™ analysis software