AUDit™ & System 824 Audiometer Calibration and Electro-acoustic Test System
|
|
Features |
Applications |
|
|
System 824: Electro-acoustic analyzer and precision SLM
Level, frequency, FM, and pulse measurements are only a small portion of the capabilities of the System 824 real time analyzer. Narrow-band FFT and real time 1/3 octave analysis speed up measurements such as THD or ambient noise measurements. Since the 824 is a complete, hand-held precision sound level meter, it is also well suited for:
measuring noise dose exposure
performing environmental noise studies
assisting in noise reduction engineering
The perfect integration of analyzer, software and couplers for fast, exhaustive testing
The 824-AUD Firmware provides internal audiometer testing functions
Larson Davis audiometer calibration systems owe their power to the precision System 824 sound level meter: its standard real time fractional octave filters are important for audiometer tests. The 824-AUD firmware is also loaded with additional features such as FM and pulse, 400-line FFT for narrow-band analysis and total harmonic distortion, etc.
Real time analysis for HL, frequency & THD
Hearing level measurements are simple with the real time 1/3 octaves of the System 824. The full spectrum is displayed without having to change filters. The 400-line FFT mode displays smaller frequency bands to locate and measure harmonics for THD measurements. A precision counter accurately samples the period of the tone stimulus and displays it along with frequency.
All pulse measurements on a single screen
When pulsed stimulus capability must be tested, simply present the tone and read all values on a single screen of the System 824. Rise, Fall, ON and OFF times are measured with millisecond accuracy. Plateau duration and over-shoot level are also averaged and displayed on the same screen.
Test frequency modulated stimuli
The characteristics of the FM presentation can be assessed just as easily. The System 824 measures minimum and maximum frequencies, calculates the carrier frequency and also measures the modulation rate.
AUDit™ Software offers test management, audiometer database, and reporting
An audiometer calibration involves much mundane but time consuming (and possibly error prone) note-taking and calculation. The AUDit™ software has been designed to simplify those steps and streamline testing.
Complete test information and definition
Measurement system: keeping track of test equipment is easy as the software maintains a database of your calibrators, microphones, couplers and 824 SLM with model, serial number and calibration date information.
Audiometer description: enter a complete description of the tested audiometer, its capabilities (such as type and frequencies), and its transducers. Future tests can recall this configuration.
Level corrections: these are done automatically from entered microphone, coupler and other responses.
Perform exhaustive calibrations
Ambient (booth) noise level test: the ambient noise of an audiometric test must not affect the patient. LD has integrated this standard test in AUDit™. Simply calibrate the microphone, then start the test. Failed frequencies are reported with a large red X.
Speaker tests, visual inspection: these are only two of the many tests that are available. Tests can recall the audiometer configurations and test instrumentation from previous calibrations.
Perform all, or select only desired tests: the main measurement screen displays a selection of tests, as well as their current status. Once a test is selected, simple prompts indicate what stimulus is required. Adjustments can be made immediately in some tests!
Generate results, reports and certificates
Results: each test displays immediate results on screen, with measured data and standard limits. It is possible to retest each failed frequency, level or function.
Custom reports and certificates: any stored calibration may be printed in whole or part. A certificate can also be printed, with your own customized certification text.
Export from database: should you desire even more flexibility, test results can be exported to your own template as .csv files.
AMC493 Artificial Mastoid
Use this innovative transducer for no-fuss bone vibrator testing
The LD AMC493 artificial mastoid is a precision mechanical coupler used to calibrate bone conduction hearing aids and audiometer bone vibrators.
The AMC493 is cost effective and simple to use. Its patented design converts the vibrator velocity output to an acoustic signal measured with the system’s sound level meter. It is integrated with the AEC100 artificial ear to perform both ear and bone conduction tests using essentially the same equipment.
The AMC493 has an extremely low thermal mass compared to mastoids that require hours to reach the 23°C calibration temperature recommended in the standard. The AMC493 is ready for use within minutes! Put it in your pocket, instead of hitting your knees carrying a heavy case.
While polymers used in other mastoids are affected by aging and environmental exposure, the AMC493 polymeric parts are completely replaced each year during its inexpensive calibration and certification.
|
Measurements and Features |
|
|
Hearing level, linearity: |
Test / adjust user selected frequencies and levels with prompts, out-of-tolerance indication |
|
Frequency accuracy: |
Precision counter averages readings of audiometric or extended frequencies |
|
Pulse measurements: |
Simultaneous test of pulsed stimulus: rise, fall, on and off times, on/off ratio and width |
|
Frequency modulation: |
Minimum, maximum frequencies, % modulation and repetition rate at all test frequencies |
|
Total harmonic distortion: |
Hands-off test of THD using FFT analysis reports fundamental and harmonic levels, % THD |
|
Narrowband, broadband: |
Narrowband stimulus level, % modulation and repetition rate test at all test frequencies |
|
Speech, crosstalk: |
Microphone, tape / CD output signal test or speech noise test, as well as crosstalk |
|
Bone vibrators: |
Hearing level and other tests for forehead or mastoid placement using AMC493 or B&K mastoid |
|
Earphones: |
RETSPLs and couplers for supra-aural (eg TDH 39, 40, 50), circumaural (eg HDA200, HV1/A), software compatibility with transducers such as in-the-ear or insert, IEC 711, HA-1 or HA-2 couplers |
|
Speakers: |
Automated tests with binaural or monaural (0, 45 or 90° placement of speakers) |
|
Ambient noise: |
Audiometric test / hearing aid fitting area allowed background noise test by 1/3 octaves |
|
System 824 Precision Analyzer |
|
|
General: |
Precision (Type 1) SLM with A,C,Flat weight, >80/105 dynamic range, int/ext power, 2MB, 824-AUD firmware, low-noise 1/2" preamp, NiMH battery, RS232 and printer cables |
|
Frequency analysis: |
1/1 octave: 16-16kHz, 1/3 octave: 12.5-20kHz, narrowband FFT: 400 lines 1,2,5,10,20 kHz |
|
2575 microphone: |
Precision 1" pressure response condenser compatible with AEC100 coupler |
|
CAL250 calibrator: |
114.0 dB (re 20 micropascals), 250 Hz +/- 0.5 Hz, one inch opening, 1/2" adaptor ADP019 |
|
Governing Standards |
|
|
AUDit™ software: |
ANSI S3.6-1996 Specification for Audiometers, ANSI S3.7-1995 Methods for Coupler Calibration of Earphones, ANSI S3.1-1991 Maximum Permissible Ambient Noise Levels for Audiometric Test Rooms |
|
System824 SLM/RTA: |
ANSI S1.4-1983 –Type 1, ANSI S1.11-1986 – Type 0C, IEC 60651 and 60804 –Type 1, IEC 61260 – Class 1, PTB approved |
|
AEC100 coupler: |
ANSI S3.7-1995 Methods For Coupler Calibration Of Earphones, IEC 60318-3 |
|
AEC101 coupler: |
ANSI S3.7-1995 Methods For Coupler Calibration Of Earphones, IEC 60318-1, IEC 60318-2 |
|
AMC493 mastoid: |
ANSI S3.13-1993, IEC 60373-1990-01 Mechanical Coupler for Measurement of Bone Vibrators (patented low thermal mass design varies from design features in standard) |
|
Physical |
|
|
SYS008 weight: |
21.5 lbs (9.80 kg) Case dimensions: 20 1/2" x 16 3/4" x 8 1/2" (52 cm x 42.5 cm x 21.6 cm) |
|
SYS009 weight: |
21.7 lbs (9.85 kg) Fiberglass reinforced airtight thermoplastic case with pressure relief |
|
|
|
|
AUDit™ software’s features and functions apply only to supported Larson Davis products. All specifications are subject to change without notice. |
|
|