division of BIOLAB |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
MTS Level Plus® Liquid Level Gauges
Level Plus Analog 4-20mA Output Selection Guide
|
|
||
|
Outputs |
Single 4-20mA with HART® |
One or Two 4-20mA outputs with HART® |
|
Lengths |
18-216 inches (451mm to 5486mm) Rigid |
|
|
Measured Parameters |
Product level/interface depending on float selection |
Level, Interface, or Temperature
|
|
Non-linearity |
0.02% F.S.
(Independent BSL) or 1/32" (0.794 mm)* |
* whichever is greater |
|
Repeatability |
0.005% F.S. or 0.005" (0.127mm)* |
*whichever is greater |
|
Mounting |
¾ NPT adjustable fitting |
¾ NPT Standard Welded or Threaded Flange Optional; Triclover Optional |
|
Wetted Parts |
316L SS |
316L SS |
|
Area Class |
CSA/FM approval intrinsically safe for Class 1, Div 1, Groups A,B,C,D,E, F&G with approved IS barriers |
|
|
Electronics Operating Temperature |
-30 to 160°F |
-30 to 160°F |
|
Integral Temperature Sensor |
Not available |
One (1) RTD at 1" from tip |
|
Zero/Span Adjust** |
Zero: Anywhere
within the active range |
HART or optional
display/keypad |
Notes:
Specifications are subject to change without notice. Consult MTS for verification of specifications critical to your needs.
* whichever is greater
** Calibration is accomplished by positioning the float and then placing a MTS supplied magnet in the “Zero” or “Span” indentation on underside of housing.
|
Hastelloy is a registered trademark of Haynes International
| Teflon is a registered trademark of Dupont Corporation |