DESCRIPTION
Ultrasonic leak detection is extremely broad based. Sensing ultrasounds generated by a
leak, the ULTRAPROBE can be used to locate leaks in
pressurized systems regardless of the type of gas used. This is especially beneficial in
areas where there is a saturation of gases or where a wide variety of gases, pressurized
vessels and vacuum processes exist.
Time and convenience are also improved with ultrasonic detection since equipment may be tested while on-line.
|
How Ultrasonic Leak
Detection Works |
|
Leak Detection Method
Ultrasound is a high frequency, short wave signal. The intensity of the ultrasound
produced by a leak drops off rapidly as the sound moves away from its source. For this
reason, the leak sound will be loudest at the leak site. Ultrasound is considered fairly
"directional" and therefore, locating the source (i.e. the location) of the leak
is quite simple.
For detection, scan the general area of a suspected leak and listen for a hissing sound (similar to the sound you hear when you fill a tire with air). Move in the direction of the loudest sound. If it is hard to determine the direction of the noise, reduce the sensitivity until direction can be established. Follow the sound and continue to reduce the sensitivity to determine the direction of the leak. In order to confirm the leak site, move the scanner back and forth over the suspect area. The sound level should increase as you pass over the leak. In some loud factory environments, frequency tuning may be required.