Industrial Technologies

division of BIOLAB 

UE Systems Ultrasonic Detection Equipment

Model UCA586 Ultrasonic Condition Alert Systems Specifications

   

PDF Datasheet | Request Info

Electrical Specifications

  • Detection Frequency: 25-50 kHz

  • Power Supply Requirements: 20-30 VDC 200 mA

  • OUTPUTS AVAILABLE:
    1. 0-10 VDC Linear output
    Transfer Function: dB / VDC
    >Scale: 1 VDC = 4dB input level
    Dynamic Measurement Range: 40 dB
    2. 4-20 mA DC Linear Output
    Transfer Function: dB/mA DC
    Scale: 1mA DC = 2.5 dB Input Level
    Dynamic Measurement Range: 40 dB
    3. Alarm Output
    Open Collector Rated @ 24 VDC, 10 mA
    Threshold Level: Adjustable Over The Ouput Range. Alarm output stops conducting when input level exceeds the threshold level (set point)
    4. Demodulated (Audio) output
    90 dBa at full scale ouput into 16 ohms
    3 dB Bandwidth approx. 6kHz
    5. Threshold Sense
    Low Impedance output which senses the threshold level (set point)
     

  • Dynamic input range: approx. 100dB

  • I/0 cable: RF Shielded, Standard 3 Meters for greater lengths consult factory

  • I/0 Connector: DB9

  • Transducer Input connector: BNC

  • Panel Adjustments: Sensitivity and threshold

  • Panel Indicators: Power "OK" (Blue)

  • Alarm, threshold exceeded (Red)

Environmental & Physical Specifications

  • Enclosure: Oil Resistant

  • Length: 4.3"

  • Width: 3.7"

  • Height: 1.9"

  • Operating Temperature: 0-60° C

  • Weight: 13.5 oz

  • Transducer: Piezo Electric

  • Stainless Steel Housing with BNC For Quick Disconnect

  • Dimensions: Diameter = 1.0", Length = 2.4" / 10/32" Thread mounting hole

  • Transducer Cable: RF Shielded, Standard 3 meters for greater lengths consult factory

  • Warranty: 1 year parts/labour

 

 

Specifications subject to change without notice.

Copyright ©1999-2000 UE Systems, Inc.