Industrial Technologies

division of BIOLAB 

IMI Industrial Monitoring Instrumentation

Model 682A05 - Machinery Fault Detector

 

PDF Datasheet l Request Info 

  • Monitors and Detects Mechanical Machinery Faults to Avert Catastrophic Failure

  • Detects Faults in Bearings and Gears due to Wear, Loss of Lubrication, Contamination, Impacting, and Cavitation

  • Powers and Accepts ICP® Accelerometer Signal Inputs

  • Utilizes Peak Detection Methodology (Patent Pending)

  • 4 to 20 mA Outputs for Peak Acceleration and Sinusoidal Vibration

  • Analog Vibration Output for Analysis and Diagnostics

The Model 682A05 is an advanced vibration signal conditioner designed to provide early warning of imminent machinery failure using PLC, DCS, SCADA, alarm, and control systems. The unit accepts a 100 mV/g ICP® accelerometer input signal and, via sophisticated signal conditioning techniques, offers two 4 to 20 mA outputs for continuous machinery health monitoring, and an analog voltage output for detailed vibration signal analysis.

Model 682A05 is designed to capture the earliest signs of bearing deterioration with a minimum of personnel training. Through a 1 KHz/5 KHz selectable high-pass filter, the first output measures “peak” g levels over a specified time interval, which is critical in the detection of early bearing faults. The second output measures “overall” vibration levels in user-selectable units, from 10 Hz to 1 KHz. This second output is ideal for detecting low frequency faults such as out-of-balance and misalignment.                                                                                                                                                                   

                                                                                                                                                                                                                                                                            © Copyright PCB Piezotronics